If your Navien boiler has suddenly stopped working and you’re seeing a fault message on the display, you’re not alone. Navien boiler error codes are designed to help diagnose what’s wrong, but they can look confusing if you’re not a heating engineer.
This guide breaks down the most common error codes, what they mean, what causes them, and how to fix them safely.
Get a quote today and take the stress out of replacing your boiler. At Boilers2Go, we offer fast, reliable installation across the UK - often as soon as the next day.
Need a new boiler?
What Are the Most Common Navien Boiler Error Codes?
Below are the most frequently reported Navien boiler error codes in the UK.
Navien error code E003
The E003 indicates an ignition failure, meaning the boiler attempted to ignite but could not produce a stable flame. This prevents the boiler from heating water or supplying central heating.
Causes
No gas supply or low gas pressure
If the boiler isn’t receiving enough gas, ignition cannot occur. This may happen if the gas meter has been turned off, credit has run out on a prepayment meter, or there’s an issue with the local gas network. Low gas pressure can also occur in cold weather when demand is high.
Air in the gas line
Following maintenance or periods of inactivity, air can become trapped in the gas supply line. This prevents consistent ignition and may require purging by a Gas Safe engineer.
Blocked burner
Dirt, soot, or debris on the burner can disrupt flame formation. A blocked burner reduces combustion efficiency and can cause repeated E003 ignition failures.
Faulty igniter or flame sensor
If the igniter cannot spark or the sensor cannot detect the flame, the boiler will shut down as a safety precaution. These components naturally wear over time and may need replacement.
Frozen or blocked condensate pipe
In UK winters, condensate pipes can freeze outside, backing up moisture into the boiler. This disrupts ignition and is one of the most common seasonal causes of E003.
How to fix error code E003
Try these steps safely:
- Check that other gas appliances work
- Reset the boiler using the front control panel
- Ensure the condensate pipe is not frozen (common in UK winters)
- Check for visible kinks in the flue (do not dismantle)
Call a Gas Safe registered engineer if:
- the code returns repeatedly
- you smell gas
- ignition components need replacing
Navien error code E012
The E012 error code relates to flame loss, meaning the flame ignites but cannot stay stable during operation.
Causes
Flue obstruction from debris or weather
Bird nests, leaves, snow, or wind-blown debris can restrict airflow. When exhaust gases cannot escape, the flame becomes unstable and the boiler shuts down.
Poor combustion due to incorrect air–gas mix
If the boiler isn’t getting the correct oxygen balance, the flame becomes weak. This can be caused by faulty calibration, blocked vents, or gas supply inconsistencies.
Moisture in ignition components
Condensation or leaks can accumulate inside the boiler and affect electrical ignition components, causing intermittent loss of flame.
Blocked heat exchanger
Limescale, sludge, or corrosion can restrict water flow and heat transfer, resulting in unstable flame behaviour and triggering E012.
Weak gas supply
If the flame loses strength mid-operation, it suggests fluctuating or inadequate gas delivery, often tied to external supply conditions.
How to fix error code E012
Homeowners can:
- Check flue terminal for obstructions such as leaves or snow
- Reset the boiler after waiting 5 minutes
A heating engineer may:
- adjust combustion
- clean burner assembly
- test gas pressure
- inspect heat exchanger
Navien error code E030
This E030 error code signals a blocked exhaust or flue issue, which can be dangerous because fumes may not be venting safely.
Causes
Blocked or iced flue
A blocked flue prevents exhaust gases from exiting safely. Ice in winter or nesting debris in warmer months can both trigger this code.
Incorrect flue installation
If the flue has been fitted with the wrong gradient, length, or sealing, airflow becomes turbulent and unsafe, leading to an automatic shutdown.
Strong winds causing backdraft
High winds can blow exhaust gases back toward the boiler, disrupting ventilation pressure. This is more common in coastal or exposed locations.
Internal fan failure
The fan ensures proper airflow through the combustion chamber. If the fan slows, sticks, or burns out, the boiler cannot safely operate.
How to fix error code E030
Do NOT attempt to use the boiler until this is resolved.
Steps:
- Inspect outdoor flue terminal visually (do not remove parts)
- Check for ice build-up in freezing weather
- Call a professional if the code persists
This error has safety implications and should be prioritised.
Navien error code E046
The E046 error code refers to low or unstable system water pressure, impacting the heating circuit.
Causes
System leaks in radiators or pipes
Even small leaks reduce water pressure over time. Drips may occur at radiator valves, pipe joints, or under flooring, causing repeated pressure drops.
Recently bled radiators
After bleeding radiators, trapped air escapes and system pressure drops. If the system isn’t topped back up, the boiler detects low pressure.
Faulty pressure sensor
If the sensor sends incorrect readings to the boiler, it may falsely detect low pressure even when the system is correctly filled.
Expansion vessel issues
A failed or deflated expansion vessel causes pressure fluctuations as heating demand changes. This is a common cause in older systems.
How to fix error code E046
Homeowners can:
- Check pressure gauge (should be around 1.0–1.5 bar)
- Use filling loop to top up system
- Reset boiler after repressurising
Call an engineer if:
- pressure drops repeatedly
- water is visible under boiler
- expansion vessel needs recharging
Navien error code E109
The E109 error code indicates a fan or air pressure switch (APS) failure, affecting airflow and combustion safety.
Causes
Faulty fan motor
If the fan cannot create the required airflow, safe combustion cannot occur. Grinding noises or intermittent running often indicate failure.
Blocked flue
Restricted airflow can trigger both E030 and E109. The APS detects incorrect pressure and shuts the boiler down to prevent unsafe burning.
Damaged APS tubing
Cracked, kinked, or loose tubing prevents the air pressure switch from detecting airflow correctly, leading to false shutdown signals.
Wiring failure
Loose, corroded, or damaged wiring interrupts communication between the fan, APS, and PCB, causing safety lockouts.
How to fix error code E109
Because this affects safe combustion, a Gas Safe engineer must diagnose it.
Possible repairs:
- fan replacement
- APS replacement
- wiring inspection
- flue testing
Navien error code E515
The E515 error code points to a PCB (Printed Circuit Board) communication fault, meaning internal components aren’t communicating properly.
Causes
Loose electrical connectors
Vibration, heat expansion, or poor installation can loosen internal wiring plugs, leading to intermittent PCB communication errors.
Moisture ingress
Humidity, leaks, or condensate issues can interfere with electronic components and cause digital errors or shutdowns.
PCB failure
The PCB is the boiler’s control brain. Component aging, overheating, or electrical surges can lead to permanent failure.
Voltage irregularities
Fluctuations in household electrical supply—often from faulty circuits or storms—disrupt internal communication and trigger E515.
How to fix error code E515
Homeowners should:
- power cycle the boiler
- check for tripped electrics
Engineers may:
- replace PCB
- test voltage supply
- reseat connections
FAQs
1. Can I clear Navien error codes by resetting the boiler?
Sometimes, yes—especially after a power dip or temporary pressure issue. If the code returns, further diagnosis is required.
2. Are Navien boiler error codes different in the UK vs USA?
Yes, UK models may feature different safety standards and code definitions due to Gas Safe regulations and flue rules.
3. Will error codes affect energy efficiency?
Yes—issues like poor combustion or low pressure can increase fuel use and reduce condensing efficiency.
4. Do Navien error codes appear during annual servicing?
Engineers can access historic stored fault logs during servicing, helping predict failures.
5. Can smart thermostats cause Navien boiler error alerts?
Incorrect wiring or incompatible controls can trigger communication-related errors.
With years of experience in boilers and home improvements in general, Myles Robinson is a passionate advocate for making home heating simpler, safer, and more affordable for households across the UK. With years of experience in the heating industry, Myles combines hands-on knowledge with a focus on customer-first service, helping homeowners choose the right boiler, understand their systems, and keep their heating running efficiently all year round. His articles break down complex topics into clear, practical advice you can trust.